<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>18012</ErrorNumber>
<ErrorFamily>Laser</ErrorFamily>
<ErrorMessage>
LASER: Communications error: No response
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The recorder should be reset.  If this does not help, check that the red LED is
lit on the laser power supply.  If it isn't, check the power supply's cables and
fuse.  Check that AC is being supplied.  If not, suspect the relay on the power
distribution board.
</text></DescriptionText>
<DescriptionText><text>
If the power supply appears ok, the cable from the laser power supply to the
laser controller should be checked.  The serial cable from the laser to the
backplane should be inspected and replaced if not loose.
</text></DescriptionText>
<DescriptionText><text>
Since the only other option is to replace the laser, the MPE should be replaced
first.  If this doesn't help, this error is likely due to a faulty laser
controller. Note that the controller and the laser are matched and therefore the
controller cannot be replaced without replacing the laser.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reboot the Platesetter.  Contact Creo Service if rebooting does not help.
</text></DescriptionText>
</OperatorAction>
<Cause>
Laser serial cable loose or faulty
</Cause>
<Cause>
Laser power supply faulty or fuse blown
</Cause>
<Cause>
Laser confused
</Cause>
<Cause>
Faulty MPE
</Cause>
<Cause>
Laser power supply to laser controller cable loose or faulty
</Cause>
<Cause>
Faulty laser controller
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:47 2008 PST
</Updated>
<Links>
</Links>
</Error>